کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6192655 1258672 2016 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
North American Multicenter Volumetric CT Study for Clinical Staging of Malignant Pleural Mesothelioma: Feasibility and Logistics of Setting Up a Quantitative Imaging Study
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی تومور شناسی
پیش نمایش صفحه اول مقاله
North American Multicenter Volumetric CT Study for Clinical Staging of Malignant Pleural Mesothelioma: Feasibility and Logistics of Setting Up a Quantitative Imaging Study
چکیده انگلیسی

BackgroundClinical tumor (T), node, and metastasis staging is based on a qualitative assessment of features defining T descriptors and has been found to be suboptimal for predicting the prognosis of patients with malignant pleural mesothelioma (MPM). Previous work suggests that volumetric computed tomography (VolCT) is prognostic and, if found practical and reproducible, could improve clinical MPM classification.MethodsSix North American institutions electronically submitted clinical, pathologic, and imaging data on patients with stages I to IV MPM to an established multicenter database and biostatistical center. Two reference radiologists blinded to clinical data independently reviewed the scans; calculated clinical T, node, and metastasis stage by standard criteria; performed semiautomated tumor volume calculations using commercially available software; and submitted the findings to the biostatistical center. Study end points included the feasibility of a multi-institutional VolCT network, concordance of independent VolCT assessments, and association of VolCT with pathological T classification.ResultsOf 164 submitted cases, 129 were evaluated by both reference radiologists. Discordant clinical staging of most cases confirmed the inadequacy of current criteria. The overall correlation between VolCT estimates was good (Spearman correlation 0.822), but some were significantly discordant. Root cause analysis of the most discordant estimates identified four common sources of variability. Despite these limitations, median tumor volume estimates were similar within subgroups of cases representing each pathological T descriptor and increased monotonically for each reference radiologist with increasing pathological T status.ConclusionsThe good correlation between VolCT estimates obtained for most cases reviewed by two independent radiologists and qualitative association of VolCT with pathological T status combine to encourage further study. The identified sources of user error will inform design of a follow-up prospective trial to more formally assess interobserver variability of VolCT and its potential contribution to clinical MPM staging.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Thoracic Oncology - Volume 11, Issue 8, August 2016, Pages 1335-1344
نویسندگان
, , , , , , , , , , , , , ,