Anterior and posterior corneal stroma elasticity after corneal collagen crosslinking treatment
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی ایمونولوژی و میکروب شناسی (عمومی)
پیش نمایش صفحه اول مقاله
Anterior and posterior corneal stroma elasticity after corneal collagen crosslinking treatment
چکیده انگلیسی


- We measured human stroma elasticity after UV-B2 crosslinking using AFM.
- There is a significant increase in anterior stroma stiffness after crosslinking.
- There is no significant change in posterior stroma stiffness after crosslinking.

The purpose of this project was to assess anterior and posterior corneal stromal elasticity after corneal collagen cross linking (CXL) treatment in human cadaver eyes using Atomic Force Microscopy (AFM) through indentation. Twenty four human cadaver eyes (12 pairs) were included in this study and divided into 2 groups (6 pairs per group). In both groups, the left eye (OS) served as a control (no riboflavin or CXL treatment was performed) and the right eye (OD) underwent CXL treatment (30 min of riboflavin pretreatment followed by 30 min of exposure to 3 mW/cm2 of ultraviolet light). In group 1, the anterior stroma was exposed by manual delamination of approximately 50 μm of the corneal stroma including Bowman's membrane. In group 2, the posterior stroma was exposed by delamination of the anterior 50% of the corneal stroma including Bowman's membrane. Delamination was performed after crosslinking treatment in the case of the treated eyes. In all eyes, the stromal elasticity was quantified using AFM through indentation. Young's modulus of elasticity for the anterior cornea (group 1) was 245.9 ± 209.1 kPa (range: 82.3-530.8 kPa) for the untreated control eyes, and 467.8 ± 373.2 kPa (range: 157.4-1126 kPa) for the CXL treated eyes. Young's modulus for the posterior cornea (group 2) was 100.2 ± 61.9 kPa (range: 28.1-162.6 kPa) for the untreated control eyes and 66.0 ± 31.8 kPa (range: 31.3-101.7 kPa) for the CXL treated eyes. Young's modulus of the anterior stroma significantly increased after CXL treatment (p = 0.024), whereas the posterior stroma did not demonstrate a significant difference in Young's modulus after CXL treatment (p = 0.170). The anterior stroma was stiffer than the posterior stroma for both the control and CXL treatment groups (p = 0.077 and p = 0.023, respectively). Our findings demonstrate that stiffness of the anterior corneal stroma after CXL treatment seems to increase significantly, while the posterior stroma does not seem to be affected by CXL.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Experimental Eye Research - Volume 116, November 2013, Pages 58-62
نویسندگان
, , , , ,