کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6452872 44948 2016 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Full length articleEvaluation of different strategies for magnetic particle functionalization with DNA aptamers
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی بیو مهندسی (مهندسی زیستی)
پیش نمایش صفحه اول مقاله
Full length articleEvaluation of different strategies for magnetic particle functionalization with DNA aptamers
چکیده انگلیسی


- Commercial magnetic particles were tested for functionalization with aptamers.
- The highest surface coverage with aptamers was found for streptavidin particles.
- Streptavidin particles also showed the greatest target capturing efficiency.
- The performance of streptavidin particles was tested in aptamer sandwich assay.
- The obtained LOD was comparable to that using antibodies as receptors.

The optimal bio-functionalization of magnetic particles is essential for developing magnetic particle-based bioassays. Whereas functionalization with antibodies is generally well established, immobilization of DNA probes, such as aptamers, is not yet fully explored. In this work, four different types of commercially available magnetic particles, coated with streptavidin, maleimide or carboxyl groups, were evaluated for their surface coverage with aptamer bioreceptors, efficiency in capturing target protein and non-specific protein adsorption on their surface. A recently developed aptamer against the peanut allergen, Ara h 1 protein, was used as a model system. Conjugation of biotinylated Ara h 1 aptamer to the streptavidin particles led to the highest surface coverage, whereas the coverage of maleimide particles was 25% lower. Carboxylated particles appeared to be inadequate for DNA functionalization. Streptavidin particles also showed the greatest target capturing efficiency, comparable to the one of particles functionalized with anti-Ara h 1 antibody. The performance of streptavidin particles was additionally tested in a sandwich assay with the aptamer as a capture receptor on the particle surface. While the limit of detection obtained was comparable to the same assay system with antibody as capture receptor, it was superior to previously reported values using the same aptamer in similar assay schemes with different detection platforms. These results point to the promising application of the Ara h 1 aptamer-functionalized particles in bioassay development.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: New Biotechnology - Volume 33, Issue 6, 25 December 2016, Pages 755-762
نویسندگان
, , ,