کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | ترجمه فارسی | نسخه تمام متن |
---|---|---|---|---|---|
657272 | 1458062 | 2015 | 8 صفحه PDF | سفارش دهید | دانلود رایگان |
We used computational analysis in order to study the cooling effects of the cylindrical tubes located inside a storage vault for spent nuclear fuel. We considered the effects of the radiative and convective heat transfer on the cooling of the cylindrical tubes based on the non-dimensional maximum permissible surface temperature. We also identified the factors that affect the cooling of cylindrical tubes by investigating the cooling effects with the same heat source as a function of the distance between the tubes, the entrance length, and the tube arrangement. The thermal performance characteristics indicated that a non-uniform staggered tube array could be used in order to improve the storage efficiency of a vault in comparison to the reference uniform in-line tube arrangement, while maintaining the tube surface temperatures at a value below the maximum permissible temperature.
Journal: International Journal of Heat and Mass Transfer - Volume 80, January 2015, Pages 301–308