کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
6719063 | 503539 | 2016 | 9 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Performance of carbonated calcium silicate based cement pastes and mortars exposed to NaCl and MgCl2 deicing salt
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
سایر رشته های مهندسی
مهندسی عمران و سازه
پیش نمایش صفحه اول مقاله
چکیده انگلیسی
This paper investigates the performance of two cementitious systems exposed to freezing or deicing salts. The first cementitious system is made using an ordinary portland cement (OPC) that reacts through hydration. The second cementitious system is made using a calcium silicate cement (CSC) that reacts and gains strength through carbonation (i.e., carbonated calcium silicate based cement (CCSC)). Two experimental techniques were used to evaluate the performance of these materials. The first technique measures the potential reactivity between the concrete paste and the deicing salt (NaCl and MgCl2) using a low temperature differential scanning calorimeter. The second technique uses a longitudinal guarded comparative calorimeter equipped with acoustic emission to assess the freeze-thaw performance of mortar samples saturated with water or deicing solutions. No chemical reaction is observed between CCSC paste and NaCl while a damaging reaction is observed between the OPC paste and NaCl due to the presence of calcium sulfoaluminate phases. A chemical reaction occurs for both the CCSC and OPC paste exposed to MgCl2: for the CCSC paste, this appears non-deleterious since relatively no reduction in dynamic elastic modulus is observed; for OPC paste, however, this is a damaging reaction due to formations of magnesium silicate hydrate and calcium/magnesium oxychloride. CCSC mortar sample saturated with water shows freezing in the large pores at approximately â5 °C and smaller pores at approximately â28 °C. Both the OPC and CCSC mortars show similar freeze-thaw performance when the system is water saturated. When the water in the pores of the mortar is replaced with a salt solution (NaCl and MgCl2), the CCSC mortar shows less freeze-thaw damage (mainly due to possessing a different pore structure) and more resistance to salt degradation (mainly due to possessing a different chemistry) than the OPC mortar does.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Construction and Building Materials - Volume 111, 15 May 2016, Pages 63-71
Journal: Construction and Building Materials - Volume 111, 15 May 2016, Pages 63-71
نویسندگان
Yaghoob Farnam, Chiara Villani, Taylor Washington, Mark Spence, Jitendra Jain, W. Jason Weiss,