کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
684921 | 889029 | 2008 | 7 صفحه PDF | دانلود رایگان |

Low water consumption in rural areas in Jordan had resulted in the production of concentrated grey water. Average COD, BOD and TSS values were 2568 mg/l, 1056 mg/l and 845 mg/l, respectively. The average grey water generation was measured to be 14 L/c.d. Three different treatment options were selected based on certain criterions, and discussed in this article. The examined treatment systems are septic tank followed by intermittent sand filter; septic tank followed by wetlands; and UASB-hybrid reactor. Advantages and disadvantages of each system are presented. It was concluded that UASB-hybrid reactor would be the most suitable treatment option in terms of compactness and simplicity in operation. The volume of UASB-hybrid reactor was calculated to be 0.268 m3 with a surface area of 0.138 m2 for each house having 10 inhabitants on average. Produced effluent is expected to meet Jordanian standards set for reclaimed water reuse in irrigating fruit trees.
Journal: Bioresource Technology - Volume 99, Issue 14, September 2008, Pages 6635–6641