Matrix metalloproteinase-9 (MMP-9) plays an important role in both physiological and pathological processes. This enzyme is a peripheral biomarker of neuroinflammation in multiple sclerosis (MS), a chronic autoimmune disease of the central nervous system. Presently, expensive magnetic resonance imaging (MRI) studies are used to monitor subclinical disease activity in MS. An alternative to costly MRI scans could be the detection of MMP-9, using a low-cost, disposable sensor system for MMP-9 suitable for home-monitoring of inflammation. This would allow an early prediction of the failure of anti-inflammatory therapies and more timely clinical intervention to limit neuronal damage and prevent disability. Herein we present the development of a disposable sensor for fast and straightforward detection of MMP-9. Biosensors were produced by coating electrodes with oxidized dextran and subsequent cross-linking with peptides containing specific cleavage sites for MMP-9. Exposure of the films to the enzyme resulted in the degradation of the films, which was monitored using impedance measurements. Sensor response was rapid, a significant impedance change was usually observed within 5Â min after the addition of MMP-9. Sensors showed a negligible response to matrix metalloproteinase-2 (MMP-2), a protease which may interfere with MMP-9 detection. The peptide sequence with the highest sensitivity and selectivity Leu-Gly-Arg-Met-Gly-Leu-Pro-Gly-Lys was selected to construct calibration curves. MMP-9 was successfully detected in a clinically relevant range from 50 to 400Â ng/ml. Two different processes of hydrogel degradation were observed on electrode surfaces with different roughness, and both appeared suitable to monitor MMP-9 activity. The sensor materials are generic and can be easily adopted to respond to other proteases by selecting peptide cross-linkers with suitable cleavage sites.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 68, 15 June 2015, Pages 660-667
Journal: Biosensors and Bioelectronics - Volume 68, 15 June 2015, Pages 660-667
نویسندگان
Anna Biela, Michael Watkinson, Ute C. Meier, David Baker, Gavin Giovannoni, C. Remzi Becer, Steffi Krause,