کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7607736 | 1493364 | 2018 | 9 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Enantioselective multiple heartcut two-dimensional ultra-high-performance liquid chromatography method with a Coreshell chiral stationary phase in the second dimension for analysis of all proteinogenic amino acids in a single run
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
A multiple heartcut (MHC) 2D-UHPLC method with UV detection has been developed for the enantioselective analysis of complex amino acid mixtures in a single run. The MHC method is based on an achiral gradient RPLC separation with 1.8â¯Î¼m C18 phase (100â¯Ãâ¯2.1â¯mm ID column) in the first dimension (1D) and enantioselective isocratic separation on a tert-butylcarbamoylquinine-based 2.7â¯Î¼m Coreshell particle column (50â¯Ãâ¯3â¯mm ID) in the second dimension (2D). Pre-column derivatization has been performed with Sanger's reagent (2,4-dinitrofluorobenzene) yielding chromogenic 2,4-dinitrophenylated amino acids (DNP-AAs). Heartcuts of 40â¯Î¼L fractions of the 1D peaks were sampled into the 2D system via a two-position four-port dual valve connected to two loop decks each equipped with six 40â¯Î¼L parking loops. Using this setup, 25 amino acids (20 proteinogenic plus allo-Thr, allo-Ile, homoserine (Hse), Orn, β-Ala) have been analyzed enantioselectively in a fully automated manner with a single chiral column within 130â¯min total run time (1D and 2D). All 2D separations together took 101.5â¯min (29 cuts with 3.5â¯min run time each) and thus the total analysis time was quite efficiently utilized. Faster separations were restricted by some software constraints which did not allow to adjust run times in 2D individually. The practical utility of this enantioselective MHC method is documented by application for the absolute configuration determination of the amino acids in gramicidin and bacitracin. Further optimizations should lead to a generic enantioselective amino acid analyzer for the quality control of synthetic peptides and the structural characterization of non-ribosomal peptides.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1562, 10 August 2018, Pages 69-77
Journal: Journal of Chromatography A - Volume 1562, 10 August 2018, Pages 69-77
نویسندگان
Ulrich Woiwode, Stefan Neubauer, Wolfgang Lindner, Stephan Buckenmaier, Michael Lämmerhofer,