کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7608726 1493387 2018 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination of free thyroid hormones in animal serum/plasma using ultrafiltration in combination with ultra-fast liquid chromatography-tandem mass spectrometry
ترجمه فارسی عنوان
تعیین هورمون های آزاد تیروئید در سرم / پلاسمای حیوانی با استفاده از اولترافیلتراسیون در ترکیب با طیف سنجی جرمی کروماتوگرافی مایع فوق سریع
کلمات کلیدی
هورمون های تیروئید رایگان فوق العاده تصفیه طیف سنجی جرمی کروماتوگرافی مایع دو طرفه، گونه های غیر انسانی، سرم / پلاسما،
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی
Thyroid hormones (THs), which mainly consist of 3, 3′, 5-triiodo-l-thyronine (T3) and L-thyroxine (T4), play a critical role in regulating biological processes such as growth and metabolism in various animal species. Thus, accurate measurement of T3 and T4, especially physiologically active free (protein-unbound) forms, in serum/plasma is needed for the evaluation of TH homeostasis. However, such high-precision determination of free THs is lacking for non-human species. The present study aimed to develop a highly sensitive and reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of six free THs in serum/plasma, which is applicable to not only humans but also non-human species. Two different physical separation steps, ultrafiltration (UF) and equilibrium dialysis (ED), were examined to obtain the free TH fraction. Several experimental conditions were carefully optimized and validated for UF or ED using the commercially available bovine serum. As a result, UF at 1100 × g and 37 °C for 30 min with a 30 kDa ultrafiltration device (Centrifree YM-30, Millipore) yielded excellent precision (CV: <10%). The optimized ED step also yielded high precision (CV: <10%) and the measurement values were approximately equal to those of UF, but at least 16 h were required to reach equilibrium. Thus, UF combined with LC-MS/MS was finally chosen, in terms of the time needed for the measurement. Acceptable accuracy (recovery: 70%-110%) and intra- and inter-day precision (CV: <10% and <12%, respectively) were obtained, when triplicate analyses in three different days were conducted using the bovine serum. The developed analytical method was successfully applied to the determination of free THs in serum/plasma samples of humans, cats, and dogs. Furthermore, comparison with free T4 concentrations measured by a common immunoassay method evidently indicated that the ultrafiltration-LC-MS/MS method developed in this study can increase the specificity and accuracy of TH measurement.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1539, 2 March 2018, Pages 30-40
نویسندگان
, , , , , , ,