کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7609433 1493398 2017 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A dispersive liquid-liquid microextraction based on solidification of floating organic droplet followed by injector port silylation coupled with gas chromatography-tandem mass spectrometry for the determination of nine bisphenols in bottled carbonated bev
ترجمه فارسی عنوان
میکروکساکتیو مایع مایع-مایع بر پایه جامد شدن قطره آلی شناور و سپس سیلایت کردن پورت انژکتور همراه با اسپکترومتری جرمی کروماتوگرافی گاز دو طرفه برای تعیین نه بسفنول در بطری های گاز دار
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی
In the present study, a method has been efficiently developed for the first time to determine nine bisphenol analogues [bisphenol A (BPA), bisphenol C (BPC), bisphenol AF (BPAF), bisphenol E (BPE), bisphenol F (BPF), bisphenol G (BPG), bisphenol M (BPM), bisphenol S (BPS), and bisphenol Z (BPZ)] together in bottled carbonated beverages (collected from the local market of Lucknow, India) using dispersive liquid-liquid microextraction process. This is based on solidification of floating organic droplet (DLLME-SFO) followed by injector port silylation coupled with gas chromatography-tandem mass spectrometry. The process investigated parameters of DLLME-SFO (including the type of extraction and disperser solvents with their volumes, effect of pH, ionic strength, and the sample volume), factors influencing to injection port derivatization like, collision energy, injector port temperature, derivatizing reagent with sample injection volume, and type of organic solvent. BPA, BPF, BPZ, and BPS were detected in each sample; whereas, other bisphenols were also detected in some carbonated beverage samples. After optimizing the required conditions, good linearity of analytes was achieved in the range of 0.097-100 ng mL−1 with coefficients of determination (R2) ≥ 0.995. Intra-day and inter day precision of the method was good, with relative standard deviation (% RSD) ≤ 10.95%. The limits of detection (LOD) and limits of quantification (LOQ) values of all bisphenols were ranged from 0.021 to 0.104 ng mL−1 and 0.070 to 0.343 ng mL−1, respectively. The recovery of extraction was good (73.15-95.08%) in carbonated beverage samples and good enrichment factors (96.36-117.33) were found. Thus, the developed method of microextraction was highly precise, fast, and reproducible to determine the level of contaminants in bottled carbonated beverages.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1528, 15 December 2017, Pages 10-17
نویسندگان
, , ,