کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7612101 | 1493550 | 2015 | 42 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Stir fabric phase sorptive extraction for the determination of triazine herbicides in environmental waters by liquid chromatography
ترجمه فارسی عنوان
برای استخراج عصاره فسفات فسفریک برای تعیین علف کش های تریازین در آب های محیطی با استفاده از کروماتوگرافی مایع، مخلوط کنید
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی
Stir fabric phase sorptive extraction (SFPSE), which integrates sol-gel hybrid organic-inorganic coated fabric phase sorptive extraction media with a magnetic stirring mechanism, is presented for the first time. Two flexible fabric substrates, cellulose and polyester were used as the host matrix for three different sorbents e.g., sol-gel poly(tetrahydrofuran), sol-gel poly(ethylene glycol), and sol-gel poly(dimethyldiphenylsiloxane). The new microextraction device has been analytically evaluated using triazine herbicides as model compounds. The factors affecting the extraction efficiency of SFPSE have been investigated and the optimal extraction conditions have been determined. Under these optimum conditions, the limits of quantification (LOQs) for sol-gel poly(ethylene glycol) coated SFPSE device in combination with UPLC-DAD for the analysis of the seven triazine herbicides were in the range of 0. 26-1.50 μg/L with precision (relative standard deviation) at 2 μg/L concentration ranging from 1.4-4.8% (intra-day, n = 5) and 6.8-11.8% (inter-day, n = 3). Enrichment factors were found between 444 and 1411 (compared to 2000 theoretical maximum). Absolute extraction recoveries were in the range of 22.2-70.5%. The developed method was applied for the determination of selected triazine herbicides from three river water samples. Relative recoveries of the target analytes, in the range from 75 to 126%, were found to be satisfactory. The combination of SFPSE with LC-MS/MS allows the improvement of the method sensitivity to the range from 0.015 μg/L to 0.026 μg/L with precision better than 10.8% expressed as relative standard deviation (RSD).
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1376, 9 January 2015, Pages 35-45
Journal: Journal of Chromatography A - Volume 1376, 9 January 2015, Pages 35-45
نویسندگان
Mercedes Roldán-Pijuán, Rafael Lucena, Soledad Cárdenas, Miguel Valcárcel, Abuzar Kabir, Kenneth G. Furton,