کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7612118 | 1493550 | 2015 | 10 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Validation of a gas chromatography-triple quadrupole mass spectrometry method for confirmatory analysis of dioxins and dioxin-like polychlorobiphenyls in feed following new EU Regulation 709/2014
ترجمه فارسی عنوان
اعتبار سنجی از روش اسپکترومتری جرمی کروماتوگرافی گازی سه گانه برای تجزیه و تحلیل تکراری دی اکسین ها و پلی کربورفیفنیل های مشابه دیوکسین در خوراک پس از مقررات جدید اتحادیه اروپا 709/2014
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی
The European Regulations laying down methods of sampling and analysis for the EU official control of levels of polychlorodibenzo-p-dioxins (PCDDs), polychloro-dibenzofurans (PCDFs), dioxin-like (DL) and non dioxin-like (NDL) PCBs in food and feed have been recently amended by EU Regulation Nos. 589/2014 and 709/2014. A major update is the recognition of gas chromatography (GC) triple quadrupole mass spectrometry (GC-QQQMS/MS) as a confirmatory tool for checking compliance with maximum levels (ML). These revisions have been initiated since this technology now exhibits similar performances to GC (magnetic sector) high resolution mass spectrometry (GC-HRMS). In this paper, we show a fully validated method for PCDD/Fs and DL-PCBs analysis in feed material of plant origin (vegetable oil) using GC-QQQMS/MS following the dedicated EU Regulation 709/2014. We show that individual analytical criteria (selectivity, linearity, quant/qual MRM transitions, accuracy around ML of 1.50Â ng WHO2005TEQ/kg, within-lab reproducibility, robustness, and background subtraction) meet the strict requirements set by the EU Regulation. We also propose a clear interpretation of instrumental limit of quantitation (iLOQ) as a 'performance-LOQ', defined in a specific way for GC-QQQMS/MS, and method limit of quantitation (mLOQ) as 'real-LOQ' that is used to report bound results. Eventually, the evaluation of measurement uncertainty, following a top-down approach and data produced with our method, demonstrates similar results than with GC-HRMS, thus offering a reliable alternative to the standard method for vegetable oil.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1376, 9 January 2015, Pages 149-158
Journal: Journal of Chromatography A - Volume 1376, 9 January 2015, Pages 149-158
نویسندگان
B. L'Homme, G. Scholl, G. Eppe, J.-F. Focant,