| کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن | 
|---|---|---|---|---|
| 7613058 | 1493577 | 2014 | 22 صفحه PDF | دانلود رایگان | 
عنوان انگلیسی مقاله ISI
												High-sensitivity analysis of anionic sulfonamides by capillary electrophoresis using a synergistic stacking approach
												
											ترجمه فارسی عنوان
													تجزیه و تحلیل حساسیت بالا سولفونامید های آنیونی توسط الکتروفورز مویرگی با استفاده از رویکرد انباشته هم افزایی 
													
												دانلود مقاله + سفارش ترجمه
													دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
																																												کلمات کلیدی
												
											موضوعات مرتبط
												
													مهندسی و علوم پایه
													شیمی
													شیمی آنالیزی یا شیمی تجزیه
												
											چکیده انگلیسی
												A synergistic stacking approach whereby field-enhanced sample injection and micelle-to-solvent stacking in capillary zone electrophoresis are combined has been developed and has been applied to the separation and quantification of anionic sulfonamides. Electrokinetic injection of the sample in a low conductivity alkaline diluent was performed for 90 s at â15 kV. Micelle-to-solvent stacking was then undertaken by hydrodynamic injection of micellar cetyltrimethylammonium bromide solution prior to the electrokinetic injection of sample that also contained 50% methanol. This combined stacking approach, when compared to a typical hydrostatic injection, provided improvements in peak height and corrected peak area in the range of 397-1024 and 758-1246, respectively. Limits of quantification in the range of 0.01-0.03 μg/mL were obtained for sulfamerazine, sulfamethazine and sulfamethizole and were sufficient for the determination of these analytes in river water. The percentage recovery and accuracy values obtained for a fortified river water sample that had been subjected to sample preparation by evaporation and reconstitution with diluent were 74-135%. Intra-day and inter-day repeatabilities for migration time, peak height, and corrected peak area were in the range 0.5-5.0% (percentage relative standard deviation, n = 8) and these relatively low values were attributed to the use of a stable capillary coating established by the successive multiple ionic-polymer layer technique.
											ناشر
												Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1349, 4 July 2014, Pages 129-134
											Journal: Journal of Chromatography A - Volume 1349, 4 July 2014, Pages 129-134
نویسندگان
												Ria Marni Tubaon, Paul R. Haddad, Joselito P. Quirino, 
											