کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7616168 1494035 2016 29 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Determination of “new psychoactive substances” in postmortem matrices using microwave derivatization and gas chromatography-mass spectrometry
ترجمه فارسی عنوان
تعیین یک ماده جدید روانگردان در ماتریس های پس مانده با استفاده از مشتقات مایکروویو و طیف سنج جرم کروماتوگرافی گاز
کلمات کلیدی
کاتینونها، فنیل اسیدهای آمینه، ماتریس بیولوژیکی جایگزین، مشتق ساز سریع مایکروویو، طیف سنجی جرم کروماتوگرافی گاز،
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی
An analytical methodology has been validated for qualitative and quantitative determinations of d-cathine (d-norpseudoehedrine), ephedrine, methcathinone, 1-(4-methoxyphenyl)-propan-2-amine (PMA), mephedrone, methedrone, 2,5-dimethoxy-4-methylamphetamine (DOM), 4-bromo-2,5-dimethoxyamphetamine (DOB), 2,5-dimethoxyphenethylamine (2C-H), 4-bromo-2,5-dimethoxyphenethylamine (2C-B), 4-iodo-2,5-dimethoxyphenethylamine (2C-I), 2-[2,5-dimethoxy-4-(ethylthio)phenyl]ethanamine (2C-T-2), 2,5-dimethoxy-4-isopropylthiophenethylamine (2C-T-4) and 2-[2,5-dimethoxy-4-(propylthio)phenyl]ethanamine (2C-T-7), in low volumes of vitreous humor (100 μL), pericardial fluid (250 μL) and whole blood (250 μL), using deutered amphetamine, ephedrine and mephedrone as internal standards. The validation parameters included selectivity, linearity and limits of detection and quantification, intra- and interday precision and trueness, recovery and stability. The method included mixed-mode solid phase extraction, followed by microwave fast derivatization and analysis by gas chromatography-mass spectrometry operated in selected ion monitoring mode. The procedure was linear between 5 and 600 ng/mL, with determination coefficients higher than 0.99 for all analytes. Intra- and interday precision ranged from 0.1 to 13.6%, while accuracy variability was within 80-120% interval from the nominal concentration at all studied levels. The extraction efficiencies ranged from 76.6 to 112.8%. Stability was considered acceptable for all compounds in the studied matrices. The developed assay was applied to authentic samples of the Laboratory of Chemistry and Forensic Toxicology, Centre Branch, of the National Institute of Legal Medicine and Forensic Sciences, Portugal.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography B - Volume 1020, 1 May 2016, Pages 14-23
نویسندگان
, , , , ,