کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7625940 1494577 2018 34 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simultaneous determination of parecoxib and its main metabolites valdecoxib and hydroxylated valdecoxib in mouse plasma with a sensitive LC-MS/MS method to elucidate the decreased drug metabolism of tumor bearing mice
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Simultaneous determination of parecoxib and its main metabolites valdecoxib and hydroxylated valdecoxib in mouse plasma with a sensitive LC-MS/MS method to elucidate the decreased drug metabolism of tumor bearing mice
چکیده انگلیسی
Parecoxib (PX), a prodrug of valdecoxib (VX), is an injectable selective COX-2 inhibitor, and is recommended for the treatment of cancer pain. PX can be rapidly hydrolyzed into its active metabolite VX, and VX is further metabolized into hydroxylated valdecoxib (OH-VX) by cytochrome P450 enzymes. However, cancer patients have been reported to possess reduced drug metabolism ability, which might cause excessive drug accumulation. Such overdose of PX significantly increased the risk of renal safety and cardiovascular events. Therefore, it is necessary to elucidate the concentration profiles of PX and its metabolites in cancer status. In this study, a sensitive, rapid and specific LC-MS/MS method for quantification of PX, VX and OH-VX in the plasma of tumor bearing mouse was developed and validated. After protein precipitation, all the analytes were separated on an Agilent ZORBAX Extend-C18 HPLC column (2.1 × 100 mm, 3.5 μm) with gradient elution. The analytes were detected by an electrospray negative ionization mass spectrometry in the multiple reaction monitoring mode. The transition m/z 369.0 → 119.0, m/z 312.9 → 117.9, m/z 329.0 → 196.0, and m/z 307.1 → 161.3 were used for monitoring PX, VX, OH-VX and IS respectively. The calibration curves of the analytes showed good linearity over the concentration range of 3-3000 ng/mL for PX and VX, and 3-1000 ng/mL for OH-VX. Intra- and inter-batch accuracies (in terms of relative error, RE < 9.9%) and precisions (in terms of relative standard deviation, RSD < 8.8%) satisfied the standard of validation. The matrix effect, recovery and stability were also within acceptable criteria. The method was successfully applied to the pharmacokinetics study of PX in tumor bearing mice, and PX and VX levels were found elevated with the growth of tumor volume, which might increase the risk of drug overdose.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Pharmaceutical and Biomedical Analysis - Volume 158, 5 September 2018, Pages 1-7
نویسندگان
, , , , , , , ,