کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
768624 1462994 2013 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Failure detection and optimization of sugar mill boiler using FMEA and Taguchi method
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Failure detection and optimization of sugar mill boiler using FMEA and Taguchi method
چکیده انگلیسی

Sugar industry plays an important role in economic development of country. Cogeneration is an important source of income for sugar industries. Boiler is one of the essential components used in cogeneration process. Unscheduled boiler outages in sugar mills are major problem resulting loss of production. The boiler may be failed due to number of reasons; some of the reasons such as mechanical failure, electrical failure and temperature sensors failure. This paper describes the failures of the fuel feeding system frequently occurred in the cogeneration boiler and gives the solution to rectify these failures by using three important tools, namely, cause and effect diagram, Failure Mode and Effect Analysis and Taguchi method.


► We collect the data from well reputed sugar industry.
► Frequent failures are identified and corrected.
► Quality and production both are increased by optimisation technique.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Engineering Failure Analysis - Volume 30, June 2013, Pages 17–26