کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
768677 1462996 2013 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Caustic corrosion in a boiler waterside tube: Root cause and mechanism
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Caustic corrosion in a boiler waterside tube: Root cause and mechanism
چکیده انگلیسی

We report a failure occurred in a boiler tube of low alloy steel, SA-210 Grade A-1. A severe thickness reduction was detected in a boiler tube during periodic investigations. Two identical parallel grooves along the horizontal tube were observed. The inner surface of the tube consisted of three distinct parts: (1) dark gray scale under the grooves, (2) hemi-elliptical grooves, and (3) brown porous scale above the grooves. Microscopic investigations and microhardness tests revealed that the microstructure and properties of the base metal is intact along the tube. Moreover, some needle shape crystals which represented Na2FeO2 and NaFeO2 compounds were observed in SEM images taken from the groove scale. An excessive amount of Na and Cu was detected by EDS in the groove. The XRD results confirmed the presence NaFeO2 which is the main product of caustic corrosion. Therefore, it was concluded that the evaporation at the waterline of the partially filled tube leaded to locally caustic concentration which dissolves the protective magnetite layer and subsequently attacked the bare metal.


► Failure analysis of boiler tube.
► Two elliptical parallel trenches were observed in a horizontal boiler tube.
► Highly concentrated caustic solution leaded to caustic corrosion in which presence of Cu intensified it.
► Formation of Na2FeO2 and NaFeO2 crystals on the surface which are needle-like.
► No microcrack was observed according to optical micrographs, SEM and microhardness.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Engineering Failure Analysis - Volume 28, March 2013, Pages 69–77
نویسندگان
, , , ,