Fast identification of O2 corrosion in economiser tubes
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Fast identification of O2 corrosion in economiser tubes
چکیده انگلیسی

Failure investigation was conducted on three tube samples via visual/metallographic examination and analysis of operational history. The investigation employed a fast-identification approach, which allowed a shorter down time and faster production recovery after tube failure. Visual and metallographic evidence showed that the tube samples had suffered from abnormally high wastage at the external and internal surfaces; the latter surface, in addition had suffered from deep pitting. Analysis of operational history confirmed the presence of dissolved O2 in the feedwater. It was concluded that leakage was primarily caused by tube thinning from internal wastage/pitting, aggravated by external wastage.


► Fast, low cost investigation is conducted on O2 corrosion of economiser tubes.
► Improper function of the deaerator allowed prolonged presence of O2.
► Presence of high O2 in feedwater caused internal wastage/pitting.
► External wastage from acid condensation was also present.
► Tube thinning/leakage resulted from internal wastage/pitting and external wastage.