This paper describes the failure of stainless steel screen mesh grade AISI 316L after being in service for only 8 months. The characterization methods included visual examination, optical microscopy, scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and metallography. The results showed that the screen mesh failed by pitting corrosion and subsequent corrosion fatigue cracking. Pitting was initiated by the attack of chlorides from PVC powder and service environment as well as the action of excessive wear. Subsequent corrosion fatigue cracking arose from the presence of chlorides along with the residual and cyclic stress concentration at the pits. Failure prevention can be achieved by annealing after wire drawing, periodic surface cleaning, and proper material selection.
Journal: Engineering Failure Analysis - Volume 17, Issue 4, June 2010, Pages 857–863