کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
769218 897376 2008 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Failure analysis of a stainless steel pipeline
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Failure analysis of a stainless steel pipeline
چکیده انگلیسی

In this study, the failure of a stainless steel (SS) pipeline supplying hydrogen to a hydro cracking reactor of a petrochemical industry is investigated. Leakage was observed in the pipeline during operation. Study revealed that the failure was by chloride stress corrosion cracking. The source of chlorine was found to be the glass wool that was wrapped on the pipeline for thermal insulation purpose. Use of SS foil beneath the thermal insulator facilitated condensation of chloride ions. The protective SS foil was destroyed by pitting corrosion followed by which the pipeline failed by stress corrosion cracking. A detailed analysis of the failure is presented in this paper.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Engineering Failure Analysis - Volume 15, Issue 5, July 2008, Pages 497–504