Based on field data and a tailored set of accelerated life tests, the drawer system of food storage in a French refrigerator was redesigned. Using a force balance analysis, the simple mechanical loads of the drawer system were evaluated. The failure modes and mechanisms found experimentally were similar to those of the failed samples in the field. Failure analysis, accelerated life tests and corrective action plans were used to identify the key control parameters and level for the mechanical drawer system. The missing controllable design parameters of the drawer system in the design phase included no corner rounding and rib thickness in the intersection areas between the box and its cover, the right, center support and left rail system. After a tailored series of accelerated life tests with corrective action plans, the B1 life of the new draw system is now guaranteed to be over 10 years with a yearly failure rate of 0.1%.
Journal: Engineering Failure Analysis - Volume 16, Issue 7, October 2009, Pages 2224–2234