کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
769934 897434 2009 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Failure analysis of a vibrating shaft in a fretting wear simulator
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Failure analysis of a vibrating shaft in a fretting wear simulator
چکیده انگلیسی

Recently, a fretting wear simulator was developed in order to evaluate the fretting wear behavior of nuclear components in high temperature and high pressure (HTHP) water conditions. After 500 h tests, however, two vibrating shafts among four were fractured, which were connected to a specimen holder jig by using a bolt. The fracture surface was examined using both an optical microscope (OM) and a scanning electron microscope (SEM) to determine the failure initiation and failure mode. It was found that the failure had initiated at a contact region between the vibrating shaft and the fuel rod holder jig and a fatigue crack was propagated although it was difficult to prove it conclusively due to the heavily oxidized fracture surface. Near the failure locations, however, the thread hole was subjected to a repeated loading due to the fact that the specimen holder jig had a circular motion for simulating a vibration motion. This suggests that the vibrating shaft failure resulted from corrosion fatigue phenomenon because the fretting test had been performed at high temperature (∼320 °C) and pressurized distilled water (∼15 MPa) conditions. In this paper, the reasons for this failure and the fracture mechanisms are revealed and discussed by using the OM and SEM results of the failure surface and the stress analysis of the contact regions between the vibrating shaft and the specimen holder jig. Finally, the above results were applied to a design change of the vibrating shaft.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Engineering Failure Analysis - Volume 16, Issue 4, June 2009, Pages 1238–1244
نویسندگان
, , ,