Elimination of upper bracket resonance in extremely high head Francis hydro-generators
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Elimination of upper bracket resonance in extremely high head Francis hydro-generators
چکیده انگلیسی
Resonance occurred in the upper bracket of extremely high head Francis hydro-generators due to rotational vibrations. The vibration source was determined from field tests and a finite element analysis (FEA) of the structure. The first order natural frequency of the integrated structure including the upper bracket and the stator frame was then altered using the FEA model. The resonance during overspeed operation was eliminated, with the results verified by field tests.