کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
770083 897450 2008 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Failure analysis and redesign of a helix upper dispenser
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Failure analysis and redesign of a helix upper dispenser
چکیده انگلیسی

Failure analysis was conducted on a fractured helix upper dispenser for a side-by-side refrigerator with ice dispenser system. To reproduce the failure modes and mechanisms causing the fracture, a tailored set of accelerated life testing were applied to sample dispensers. Using bond graphs and state equations, key noise parameters in the assembly, including a variety of mechanical loads, were analyzed. The failure modes and mechanisms found experimentally were identical with those of the failed sample. To correct the problem, the key controllable design parameters of the helix upper dispenser were modified by eliminating gaps and enforcing ribs. The B1 life of the new design is now guaranteed to be over 14 years with a yearly failure rate of 0.021%.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Engineering Failure Analysis - Volume 15, Issue 6, September 2008, Pages 642–653