کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7713193 1497427 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Managing energy recovered from waste tail gas in a full-scale refinery plant
ترجمه فارسی عنوان
مدیریت انرژی از گاز ضایعات زباله در یک کارخانه پالایشگاه کامل به دست می آید
موضوعات مرتبط
مهندسی و علوم پایه شیمی الکتروشیمی
چکیده انگلیسی
Great savings of fuel consumption and an almost zero-discharge of carbon pollutants can be achieved by the direct reuse of the recovered tail gas as furnace fuel. This paper presents the results of on-site studies using a full-scale furnace to demonstrate the simple adjustments of the furnace operational parameters. The results reveal that when the residual oxygen concentration in the excess air is reduced from 3.6 to 2.4%, the furnace thermal efficiency is raised from 81.9 to 83.2%. Adjusting the furnace damper opening angle from 45 to 39° will lead to annual savings of 1.9 × 106 m3 natural gas consumption. This paper also presents the use of a membrane separation method to concentrate the hydrogen containing in the tail gas as from 78.7 to 93.9 mol%. The concentrated hydrogen gas is expected to be a valuable material to produce high value added products.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Hydrogen Energy - Volume 40, Issue 46, 14 December 2015, Pages 16070-16076