Failure analysis of H13 working die used in plastic injection moulding
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Failure analysis of H13 working die used in plastic injection moulding
چکیده انگلیسی

The present study is focused on the failure of a die used in plastic injection moulding. The die was made from AISI H13 steel and was intended for the production of plastic cups used for the outer closure of cylindrical aluminium cans in coffee packaging. The appearance of the die provides a clear picture of degradations. Extended corrosion damage on various areas of the metallic part and a wide crack can be observed by the naked eye. Hardness measurements and chemical analysis eliminated the probability of faulty material selection or improper heat treatment. Visual inspection, macro-examination and microscopic observations of representative failed parts revealed that the failure was caused by corrosion that led to the total cracking of the die. The design deficiency and improper cooling conditions generated a complex fatigue-corrosion cracking mechanism that lead to the damage of the die after half of it’s predicted service life.


► A study on the failure of a die used in plastic injection moulding.
► The design deficiency and improper cooling assumed as the main reason of failure.
► Some recommendations are given in order to avoid similar future situations.