کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
79218 | 49350 | 2011 | 8 صفحه PDF | دانلود رایگان |

Temperature control of solar cells at high concentrations is a key issue. Short-term efficiency drop and long-term degradation should be avoided by effective cooling methods. Liquid immersion cooling eliminates the contact thermal resistance of back cooling and should improve cell performance. A 250X dish concentrator with two-axis tracking was utilized to evaluate a new CPV system using de-ionized water for immersion cooling. Time-dependent temperature distributions of the PV module of high power back point-contact cells were measured, as well as the I–V curves. The cooling capacities of the liquid immersion approach are very favorable. The module temperature can be cooled to 45 °C at a 940 W/m2 direct normal irradiance, 17 °C ambient temperature and 30 °C water inlet temperature. The temperature distribution of the module is quite uniform, but the electrical performance of the cell module degrades after a fairly long time immersion in the de-ionized water.
Journal: Solar Energy Materials and Solar Cells - Volume 95, Issue 2, February 2011, Pages 538–545