کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
80398 49384 2009 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Cycle test and degradation analysis of WO3/PC+LiClO4/CeO2·TiO2 electrochromic device
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی کاتالیزور
پیش نمایش صفحه اول مقاله
Cycle test and degradation analysis of WO3/PC+LiClO4/CeO2·TiO2 electrochromic device
چکیده انگلیسی

We fabricated an electrochromic full cell device adopting WO3 as a working electrode, and 1 M LiClO4 in PC with 3% water addition as an electrolyte and CeO2·TiO2 with various thicknesses as an ion storage layer. CeO2·TiO2 with less than 100 nm shows large charge density but the long-term cyclability is not good due to lithium ion diffusion into ITO thin film. Therefore, the thickness of CeO2·TiO2 ion storage layer should be coated at more than 200 mm/min. Long-term cycle test results show that CeO2·TiO2 ion storage layer with more than 150 nm thickness and two time coating enhance the long-term stability. SIMS analysis results show that the degradation is due to the remaining lithium ion in the working electrode, WO3.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Solar Energy Materials and Solar Cells - Volume 93, Issue 12, December 2009, Pages 2056–2061
نویسندگان
, , ,