کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8131522 1523240 2014 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Real-Time Sonoelastography of Salivary Glands for Diagnosis and Functional Assessment of Primary Sjögren's Syndrome
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم آکوستیک و فرا صوت
پیش نمایش صفحه اول مقاله
Real-Time Sonoelastography of Salivary Glands for Diagnosis and Functional Assessment of Primary Sjögren's Syndrome
چکیده انگلیسی
The purpose of this study was to investigate the value of real-time sonoelastography (RTS) of salivary glands for the diagnosis and assessment of glandular damage in primary Sjögren's syndrome (pSS). After institutional review board approval, 45 pSS patients, 24 sicca patients and 11 healthy controls were investigated prospectively. Questionnaires were completed and Saxon and Schirmer tests and routine blood tests carried out in all patients. All patients underwent B-mode ultrasonography and RTS of parotid and submandibular glands. Abnormal findings were graded from 0 to 48 and from 0 to 16, respectively. Sialoscintigraphy was done according to a routine protocol; scoring ranged from 0 to 12. Statistical analysis comprised receiver operating characteristic curve and multivariate regression analysis. Patients with pSS had higher B-mode (median score = 25 [range: 2-44] vs. 9 [1-20], p < 0.001) and RTS (6.5 [2-13] versus 4 [1-9], p < 0.001) scores than controls with sicca syndrome, yielding areas under the curve of 0.83 and 0.85 (p < 0.05 each), respectively for pSS diagnosis. In cases with an inconclusive B-mode ultrasonography result, RTS (cutoff score: ≥6) led to a sensitive (66.7%) and specific (85.7%) classification of patients and sicca controls. In multivariate regression analysis, RTS (regression coefficient = -0.48, p = 0.005), but not B-mode ultrasonography, reflected impaired salivary gland function according to the Saxon test, whereas none of the subjective measures of dryness or discomfort were related to ultrasonography results. B-mode and RTS results were both associated with sialoscintigraphy scores (regression coefficient = 0.66, p < 0.001, and regression coefficient = 0.55, p = 0.001, respectively). Reproducibility of B-mode ultrasonography and RTS was good, with intra-class correlation coefficients of 0.93 (95% confidence interval: 0.57-0.98) and 0.93 (95% confidence interval: 0.79-0.98), respectively. In summary, RTS might be a useful adjunct to B-mode ultrasonography for diagnosis and assessment of salivary gland impairment in primary Sjögren's syndrome.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Ultrasound in Medicine & Biology - Volume 40, Issue 12, December 2014, Pages 2759-2767
نویسندگان
, , , , , , , , , , , , ,