Radiation treatment planning - برنامه ریزی تابش تابشVolumetric-modulated arc therapy - درمان با قوس مدولاتور حجمیTreatment planning systems - سیستم های برنامه ریزی درمانیElectron beam therapy - پرتو الکترون درمانیConformal radiation therapy - پرتو درمان متعارفintensity-modulated radiation therapy - پرتودرمانی شدید مدولاسیون
موضوعات مرتبط
مهندسی و علوم پایه
فیزیک و نجوم
تشعشع
پیش نمایش صفحه اول مقاله
چکیده انگلیسی
Eclipse is a 3-dimensional (3D) treatment planning system for radiation therapy offered by Varian Medical Systems, Inc. The system has the network connectivity for the electronic transfer of image datasets and digital data communication among different equipment. The scope of this project for this special issue of Medical Dosimetry on 3D treatment planning systems is the assessment of planning tools in the external beam planning module of Eclipse to generate optimized treatment plans for patients undergoing external beam radiation therapy. This treatment planning system is relatively mature to be able to generate (1) simple treatment plans, (2) conformal radiation therapy plans, (3) static intensity-modulated radiation therapy (IMRT) plans, (4) volumetric-modulated arc therapy (VMAT) plans, and (5) treatment plans for electron beam therapy. The treatment planning tools are relatively plentiful to assist in the radiation therapy treatment planning. Some new features have been incorporated in the latest version and are helpful for making high-quality treatment plans. However, the location of the tools is not intuitive, and hence, familiarity with the user interface is essential to the efficient use of the treatment planning system. In addition, there are a number of dose algorithms available for the computation of dose distributions. The understanding of each dose computation algorithm is essential for the optimal use of this treatment planning system.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Medical Dosimetry - Volume 43, Issue 2, Summer 2018, Pages 195-204
Journal: Medical Dosimetry - Volume 43, Issue 2, Summer 2018, Pages 195-204
نویسندگان
Cheng B. PhD, SiCong DSc, Frank CMD, Janice CMD, Christopher A. MD,