| کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن | 
|---|---|---|---|---|
| 8249108 | 1533352 | 2017 | 7 صفحه PDF | دانلود رایگان | 
عنوان انگلیسی مقاله ISI
												Three-dimensional printer-generated patient-specific phantom for artificial in vivo dosimetry in radiotherapy quality assurance
												
											دانلود مقاله + سفارش ترجمه
													دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
																																												موضوعات مرتبط
												
													مهندسی و علوم پایه
													فیزیک و نجوم
													تشعشع
												
											پیش نمایش صفحه اول مقاله
												 
												چکیده انگلیسی
												Pretreatment intensity-modulated radiotherapy quality assurance is performed using simple rectangular or cylindrical phantoms; thus, the dosimetric errors caused by complex patient-specific anatomy are absent in the evaluation objects. In this study, we construct a system for generating patient-specific three-dimensional (3D)-printed phantoms for radiotherapy dosimetry. An anthropomorphic head phantom containing the bone and hollow of the paranasal sinus is scanned by computed tomography (CT). Based on surface rendering data, a patient-specific phantom is formed using a fused-deposition-modeling-based 3D printer, with a polylactic acid filament as the printing material. Radiophotoluminescence glass dosimeters can be inserted in the 3D-printed phantom. The phantom shape, CT value, and absorbed doses are compared between the actual and 3D-printed phantoms. The shape difference between the actual and printed phantoms is less than 1 mm except in the bottom surface region. The average CT value of the infill region in the 3D-printed phantom is â6â¯Â±â¯18â¯Hounsfield units (HU) and that of the vertical shell region is 126â¯Â±â¯18â¯HU. When the same plans were irradiated, the dose differences were generally less than 2%. These results demonstrate the feasibility of the 3D-printed phantom for artificial in vivo dosimetry in radiotherapy quality assurance.
											ناشر
												Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Physica Medica - Volume 44, December 2017, Pages 205-211
											Journal: Physica Medica - Volume 44, December 2017, Pages 205-211
نویسندگان
												Takeshi Kamomae, Hidetoshi Shimizu, Takayoshi Nakaya, Kuniyasu Okudaira, Takahiro Aoyama, Hiroshi Oguchi, Masataka Komori, Mariko Kawamura, Kazuhiro Ohtakara, Hajime Monzen, Yoshiyuki Itoh, Shinji Naganawa,