کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
867323 909780 2012 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Electrogenerated chemiluminescence biosensing method for the detection of DNA methylation and assay of the methyltransferase activity
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Electrogenerated chemiluminescence biosensing method for the detection of DNA methylation and assay of the methyltransferase activity
چکیده انگلیسی

A novel electrogenerated chemiluminescence (ECL) biosensing method for highly sensitive detection of DNA methylation and assay of the CpG methyltransferase (M. SssI) activity was developed on basis of enzyme-linkage reactions and ruthenium complex served as an ECL tag. The ECL biosensing electrode was fabricated by self-assembling 5′-thiol modified 32-mer single-strand DNA (ss-DNA)-tagged with ruthenium bis (2,2′-bipyridine) (2,2′-bipyridine-4,4′-dicarboxylic acid)-ethylenediamine on the surface of a gold electrode, and then hybridized with complementary ss-DNA to form duplex DNA (ds-DNA). When M. SssI and S-adenosylmethionine were introduced, all cytosine residues within 5′–CG-3′ of ds-DNA on the biosensing electrode were methylated. After the methylated biosensing electrode was treated by HpaII endonuclease, the un-methylated cytosines were cleaved, thus led to decrease ECL signal. The ECL intensity of ECL biosensing electrode is related to the methylation level and M. SssI activity in a fixed concentration HpaII endonuclease. The increased ECL intensity was direct proportion to M. SssI activity in the range from 0.05 to 100 U/mL with a detection limit of 0.02 U/mL. This work demonstrates that the combination of the enzyme-linkage reactions with a highly sensitive ECL technique is a great promising approach for the detection of DNA methylation level, assay of the activity of MTase, and evaluation of the capability of inhibitors for the methyltransferase.


► A novel ECL biosensing method for highly sensitive detection of DNA methylation and assay of the methyltransferase activity was developed.
► The ECL biosensing method is based on enzyme-linkage reactions and ruthenium complex served as an ECL label.
► Compared with the traditional method, the ECL biosensing method is PCR-free, nonradioactive, simple and sensitive, achieved a lower detection limit of 0.02 U/mL.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 38, Issue 1, October–December 2012, Pages 407–410
نویسندگان
, , , ,