کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
868809 909814 2010 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Amperometric detection of benzoyl peroxide in pharmaceutical preparations using carbon paste electrodes with peroxidases naturally immobilized on coconut fibers
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Amperometric detection of benzoyl peroxide in pharmaceutical preparations using carbon paste electrodes with peroxidases naturally immobilized on coconut fibers
چکیده انگلیسی

This paper describes the applications of a new carbon paste electrode containing fibers of coconut (Cocus nucifera L.) fruit, which are very rich in peroxidase enzymes naturally immobilized on its structure. The new sensor was applied for the amperometric quantification of benzoyl peroxide in facial creams and dermatological shampoos. The amperometric measurements were performed in 0.1 mol L−1 phosphate buffer (pH 5.2), at 0.0 V (versus Ag/AgCl). On these conditions, benzoyl peroxide was rapidly determined in the 5.0–55 μmol L−1, with a detection limit of 2.5 μmol L−1 (s/n = 3), response time of 4.1 s (90% of the steady state) and sensitivity limit of 0.33 A mol L−1 cm−2. The amperometric results are in good agreement with those obtained by spectrophotometric technique, used as a standard method.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 25, Issue 5, 15 January 2010, Pages 1143–1148
نویسندگان
, , , , ,