کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
876219 | 910830 | 2013 | 10 صفحه PDF | دانلود رایگان |

IntroductionThe strengthening effect of prophylactic internal fixation (PIF) with a bone plate at the radial osteocutaneous flap donor site has previously been demonstrated using the sheep tibia model of the human radius. This study investigated whether a finite element (FE) model could accurately represent this biomechanical model and whether stress or strain based failure criteria are most appropriate.MethodsAn FE model of an osteotomised sheep tibia bone was strengthened using 4 types of plates with unilocking or bicortical screw fixation. Torsion and 4-point bending simulations were performed. The maximum von Mises stresses and strain failure criteria were studied.ResultsThe strengthening effects when applying stress failure criteria [factor 1.76–4.57 bending and 1.33–1.80 torsion] were comparable to the sheep biomechanical model [factor 1.73–2.43 bending and 1.54–2.63 torsion]. The strongest construct was the straight 3.5 mm stainless steel unilocking plate. Applying strain criteria the strongest construct was the straight 3.5 mm stainless DCP plate with bicortical screw fixation.ConclusionsThe FE model was validated by comparison with the sheep tibia model. The complex biomechanics at the bone-screw interface require further investigation. This FE modelling technique may be applied to a model of the human radius and other sites.
Journal: Medical Engineering & Physics - Volume 35, Issue 10, October 2013, Pages 1421–1430