کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
8799759 | 1604172 | 2018 | 8 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Voluntary muscle activation and evoked volitional-wave responses as a function of torque
ترجمه فارسی عنوان
فعال سازی داوطلبانه عضلات و واکنش موج واکنشی به عنوان عملکرد گشتاور موجب شد
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
ICCRTTRMSFCRMVCH-reflex - H-رفلکسEMG - الکترومیوگرافیelectromyography - الکترومیوگرافیITT - اینجاNerve stimulation - تحریک عصبیTranscutaneous electrical nerve stimulation - تحریک عصبی الکتریکی پوستیanalysis of variance - تحلیل واریانسANOVA - تحلیل واریانس Analysis of varianceInterpolated twitch technique - تکنیک درهم آمیختهmaximal voluntary contraction - حداکثر انقباض داوطلبانهTwitch interpolation - درهم آمیختنTENS - ده هاflexor carpi radialis - رادیالی فیکسور کپورHoffman reflex - رفلکس هوفمنintraclass correlation coefficient - ضریب همبستگی داخل کلاسیNeuromuscular function - عملکرد عضلانی عضلانیVoluntary activation - فعال سازی داوطلبانهM-wave - موج م
موضوعات مرتبط
علوم پزشکی و سلامت
پزشکی و دندانپزشکی
ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی
Introduction: This study employed a unique stimulation paradigm which allowed for the simultaneous assessment of voluntary activation levels (VA) via twitch-interpolation, and the evoked V-wave responses of the plantar flexors during submaximal and maximal contractions. Test-retest reliability was also examined. Methods: Fourteen participants repeated a stimulation protocol over four visits to assess VA and evoked V-wave amplitude across torque levels ranging from 20% to 100% MVC. MVC torque and EMG amplitude were also measured. Results: VA increased nonlinearly with torque production and plateaued by 80% MVC. V-wave amplitude increased linearly from 20% to 100% MVC. There were no differences in any dependent variable across visits (pâ¯>â¯0.05). VA demonstrated moderate to substantial reliability across all torque levels (ICCâ¯=â¯0.76-0.91) while V-wave amplitude exhibited fair to moderate reliability from 40% to 100% (ICCâ¯=â¯0.48-0.74). Discussion: We were able to reliably collect VA and the V-wave simultaneously in the plantar flexors. Collection of VA and V-wave during the same contraction provides distinct information regarding the contribution of motor-unit recruitment and descending cortico-spinal drive/excitability to force production.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Electromyography and Kinesiology - Volume 41, August 2018, Pages 1-8
Journal: Journal of Electromyography and Kinesiology - Volume 41, August 2018, Pages 1-8
نویسندگان
Robert E. Hight, Alwyn T. Quarshie, Christopher D. Black,