کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
8973679 | 1552509 | 2005 | 12 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Calibration and validation of the 14C-labelled polyethylene glycol-binding assay for tannins in tropical browse
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
علوم زیستی و بیوفناوری
علوم کشاورزی و بیولوژیک
علوم دامی و جانورشناسی
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
This study evaluates the radiolabelled polyethylene glycol (PEG)-binding procedure [Silanikove, N., Shinder, D., Gilboa, N., Eyal, M., Nitsan, Z., 1996. Polyethylene glycol-binding to plant samples as an assay for the biological effects of tannins: predicting the negative effects of tannins in Mediterranean browse on rumen degradation. J. Agric. Food Chem. 44, 3230-3234] for tannin analysis, using 27 tropical browse plants. In this method, the amount of PEG bound to a plant sample is assumed to be a reflection of its tannin content. The method was modified to exclude the use of non-tanniniferous substrate for estimating non-specific binding (NSB) in tannin-containing substrates. Non-specific binding values varied widely (0.4-2.8Â mg PEG/100Â mg DM tannin-free substrate) when the tannin-free substrate was changed from wheat straw to either rye grass or maize shoots. We therefore propose a modified radiolabelled PEG-binding method to estimate the level of PEG-binding (PEGb) to tannin-containing foliage without using tannin-free substrate to correct for non-specific binding. In this approach, incremental levels of each tanniniferous substrate were used to generate PEGb values. The resultant linear response was analysed and tannin activity was expressed as the slope of the response curve (PEGbSlope) observed for each substrate. The slope takes into account the non-specific binding in each substrate, thus PEGbSlope does not require correction for NSB using tannin-free samples. This approach improved the correlation between PEGb and the 125I-labelled bovine serum albumin precipitation assay. Relationships between the modified PEG-binding assay and radiolabelled bovine serum albumin assay, in vitro tannin bioassay and colorimetric assays are presented.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Animal Feed Science and Technology - Volume 122, Issues 1â2, 19 August 2005, Pages 29-40
Journal: Animal Feed Science and Technology - Volume 122, Issues 1â2, 19 August 2005, Pages 29-40
نویسندگان
V. Mlambo, H.P.S. Makkar,