کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
9748837 | 1493793 | 2005 | 9 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Band acceleration device for enhanced selectivity with tandem-column gas chromatography
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
An electrically heated and air cooled metal sheath surrounding the first 50Â cm of the second column in a series-coupled, capillary-column ensemble of a non-polar and a polar column is used to obtain enhanced isothermal separation of component pairs that are separated by the first column in the ensemble but co-elute from the ensemble by virtue of the different selectivity of the two columns. As the first of the two components passes into the second column, a current pulsed through the metal sheath rapidly heats the first 50Â cm of the second column thus accelerating the band for the first component. Ensemble retention-time shifts of several seconds are easily obtained. The device is then rapidly cooled to quiescent oven temperature by a flow of pressured air through the space between the metal sheath and the fused silica capillary column and an additional flow through a larger, co-axial plastic tube. Both heating and cooling require only a few seconds. If substantial cooling of the device occurs before the band for the second component enters the device, the band experiences less thermally-induced acceleration with the result that the separation of the two targeted components is enhanced in the ensemble chromatogram with no significant change in the pattern of peaks for the other mixture components. If the device is cooled to a temperature below oven temperature before the arrival of the band for the second component, this band will be slowed, and further enhancement of separation is achieved in the ensemble chromatogram. A band trajectory model, based on retention factor versus temperature data for the two components in the two columns, is used to predict peak separation and to aid in the selection of temperature-pulse initiation times.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1086, Issues 1â2, 9 September 2005, Pages 151-159
Journal: Journal of Chromatography A - Volume 1086, Issues 1â2, 9 September 2005, Pages 151-159
نویسندگان
Mark Libardoni, Megan McGuigan, Young J. Yoo, Richard Sacks,