کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10133405 1645592 2018 28 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Impacts of energy distribution and electric field on membrane fouling control in microbial fuel cell-membrane bioreactor (MFC-MBR) coupling system
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی تکنولوژی و شیمی فرآیندی
پیش نمایش صفحه اول مقاله
Impacts of energy distribution and electric field on membrane fouling control in microbial fuel cell-membrane bioreactor (MFC-MBR) coupling system
چکیده انگلیسی
To investigate the influence of energy allocation on membrane fouling, three coupling systems at different concentrations of mixed liquid suspended solids (MLSS) and a control system without microbial fuel cell (MFC) were established. The results show that MFC acted negative effect in low-loading stage (0.59 kg-COD·m−3·d−1), while high MLSS acted active effect on organics degradation in high-loading stage (2.00 kg-COD·m−3·d−1), and electric field could be a positive factor with sufficient energy. Besides, membrane filtration experiments in the electric field with microbial contaminants indicate that soluble microbial products (SMP) and loosely bound extracellular polymeric substances (LB-EPS) had greater tendencies to cause irreversible membrane fouling. SMP and the residual cell liquid (Cell) were more susceptible than extracellular polymeric substances (EPS), demonstrating that the irreversible fouling was reduced mainly due to SMP decrease in the electric field.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Bioresource Technology - Volume 269, December 2018, Pages 339-345