کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
10153071 | 1666193 | 2018 | 33 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
An integrated microfluidic platform to perform uninterrupted SELEX cycles to screen affinity reagents specific to cardiovascular biomarkers
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
CNCpolydimethysiloxanetris-acetate-EDTAPluronic P123P123EMVdeoxyribonucleotideTRISNT-proBNPdNTPNIHEtBrSELEXPBSPDMSdsDNAE. coliBSA - BSACVDs - CVD هاdouble-stranded DNA - DNA رشته ایbovine serum albumin - آلبومین سرم گاوethidium bromide - اتیدیوم برومایدEscherichia coli - اشریشیا کُلیCapillary electrophoresis - الکتروفورزمویرگیCardiovascular diseases - بیماری قلبی-عروقی Tris(hydroxymethyl)aminomethane - تریس (هیدروکسی متیل) آمینومتانSurface plasmon resonance - تشدید پلاسمون سطحیSPR - تشدید پلاسمون سطحیTAE - توsystematic evolution of ligands by exponential enrichment - تکامل سیستماتیک لیگاند ها با غنی سازی نمایشیDissociation constants - دائمی جداسازیRoom temperature - دمای اتاقNational Institutes of Health - مؤسسات ملی بهداشتPhosphate-buffered saline - محلول نمک فسفات با خاصیت بافریbase-pairs - پایه جفتPMMA - پلی (متیل متاکریلات) Poly (methyl methacrylate) - پلی متیل متاکریلاتCreatine kinase - کراتین کینازDe-ionized - یونیزه شده
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
چکیده انگلیسی
As cardiovascular diseases (CVD) are responsible for millions of deaths annually, there is a need for rapid and sensitive diagnosis of CVD at earlier stages. Aptamers generated by systematic evolution of ligands by exponential enrichment (SELEX) processes have been shown to be superior to conventional antibody-based cardiac biomarker detection. However, SELEX is a complicated, lengthy procedure requiring multiple rounds of extraction/amplification and well-trained personnel. To circumvent such issue, we designed an automated, miniaturized SELEX platform for the screening of aptamers towards three protein biomarkers associated with CVDs: N-terminal pro-peptide of B-type natriuretic peptide, human cardiac troponin I, and fibrinogen. The developed microfluidic platform was equipped with microfluidic devices capable of sample transport and mixing along with an on-chip nucleic acid amplification module such that the entire screening process (5 rounds of selection in 8â¯h.) could be performed consecutively on a single chip while consuming only 35â¯ÂµL of reagents in each cycle. This system may therefore serve as a promising, sensitive, cost-effective platform for the selection of aptamers specific for CVD biomarkers.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 122, 30 December 2018, Pages 104-112
Journal: Biosensors and Bioelectronics - Volume 122, 30 December 2018, Pages 104-112
نویسندگان
Anirban Sinha, Priya Gopinathan, Yi-Da Chung, Hsin-Ying Lin, Kuang-Hsien Li, Hsi-Pin Ma, Po-Chiun Huang, Shu-Chu Shiesh, Gwo-Bin Lee,