The development of an on-line process monitoring and control system for the automatic dosing of ammonia for production of Low Methoxylated Amidated (LMA) pectin is described. The system is based on on-line optical fibre Near Infra-Red (NIR) transmittance spectroscopy of the amidation liquid, consisting of ammonia, isopropylic alcohol, water and minor impurities. The focus in this paper is on the chemometric calibration development and validation, and the improvement on the ammonia dosing for the production. Feasibility studies revealed that the calibration for ammonia, based on NIR transmittance spectra (spectral region from 5300 to 11 000 cmâ1) is highly temperature dependent in the range â9-20 °C, but careful choice of spectral pre-processing and wavelength selection could eliminate the temperature dependency. Using the first derivative of the NIR spectra and the selection of the spectral region 5423-6658 cmâ1, the average Partial Least Squares regression prediction error was reduced to 1.75% of the full range of the initial calibration, as determined from an independently validated data set one full year after initial implementation in the factory.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chemometrics and Intelligent Laboratory Systems - Volume 76, Issue 2, 28 April 2005, Pages 149-161
Journal: Chemometrics and Intelligent Laboratory Systems - Volume 76, Issue 2, 28 April 2005, Pages 149-161
نویسندگان
Christian B. Zachariassen, Jan Larsen, Frans van den Berg, Søren Balling Engelsen,