کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
10547820 965301 2011 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Titania immobilized polypropylene hollow fiber as a disposable coating for stir bar sorptive extraction-high performance liquid chromatography-inductively coupled plasma mass spectrometry speciation of arsenic in chicken tissues
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Titania immobilized polypropylene hollow fiber as a disposable coating for stir bar sorptive extraction-high performance liquid chromatography-inductively coupled plasma mass spectrometry speciation of arsenic in chicken tissues
چکیده انگلیسی
The bottleneck of applying stir bar sorptive extraction (SBSE) to elemental speciation analysis is lack of suitable extraction phases with good affinities to different elemental species. In this paper, a newly high polar extraction phase of titania immobilized polypropylene hollow fiber (TiO2-PPHF) was prepared by sol-gel immersion and low temperature hydrothermal process and the obtained TiO2-PPHF inherits the adsorption properties of TiO2 and the toughness of PPHF. With a suitable size of stainless steel magnetic bar inserted into the prepared TiO2-PPHF, a disposable TiO2-PPHF coating stir bar was obtained. The prepared TiO2-PPHF was characterized by X-ray diffraction spectrometry and scanning electron microscopy and the significant parameters affecting the extraction efficiency of different arsenic species were studied. Based on the above facts, a new method of SBSE combined with high performance liquid chromatography (HPLC)-inductively coupled plasma mass spectrometry (ICP-MS) was developed for the speciation of phenyl arsenic compounds and their possible transformation products in chicken tissues. Under the optimal conditions, limits of detection (LODs) of the developed method for eight target arsenic species were in the range of 11.4-64.6 ng L−1 with enrichment factors of 8.5-22.3 (theory enrichment factor was 50), and the relative standard deviations (RSDs) were varying from 6.3 to 12.6% (cAsIII/V = 5 μg L−1, cMMA,DMA,p-ASA,4-OH,3-NHPAA,PA,4-NPAA = 10 μg L−1, n = 7). The proposed method was successfully applied to the speciation of arsenic in chicken meat/liver samples and the recoveries for the spiked samples were in the range of 78.5-120.4%. In order to validate the accuracy of the proposed method, a certified reference material of BCR-627 tuna fish tissue was analyzed and the determined values were in good agreement with the certified values. The TiO2-PPHF was demonstrated to be a highly selective coating for the target arsenic species, and could be easily prepared in batches with low cost. In addition, with the disposable coating, the carry-over effect commonly encountered in conventional SBSE was avoided.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1218, Issue 1, 7 January 2011, Pages 1-9
نویسندگان
, , , , ,