کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1055325 1485236 2016 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Electrocoagulation using a rotated anode: A novel reactor design for textile wastewater treatment
ترجمه فارسی عنوان
الکتروکواگولاسیون با استفاده از یک آنودای چرخشی: طراحی جدید رآکتور برای درمان فاضلاب نساجی
کلمات کلیدی
الکترو کلاژن، مصرف الکترود، فاضلاب نساجی، راکتور آنود شده چرخانده است
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
چکیده انگلیسی


• A novel rotated bed electrocoagulation (EC) reactor was developed for the treatment of textile wastewater.
• The electrode consumption, energy consumption and operating costs of the novel reactor were found to below.
• The removal efficiencies of textile wastewater contaminants were high during the initial 10 min of reaction time.
• Up to 99.99% of phenol was removed in the reactor system.

This paper investigates the optimum operational conditions of a novel rotated bed electrocoagulation (EC) reactor for the treatment of textile wastewater. The effect of various operational parameters such as rotational speed, current density (CD), operational time (RT), pH, temperature, and inter-electrode distance (IED) on the pollutant removal efficiency were examined. In addition, the consumption of aluminum (Al) and electrical energy, as well as operating costs at optimum conditions were also calculated. The results indicated that the optimum conditions for the treatment of textile wastewater were achieved at CD = 4 mA/cm2, RT = 10 min, rotational speed = 150 rpm, pH = 4.57, temperature = 25 °C, and IED = 1 cm. The electrode consumption, energy consumption, and operating costs were 0.038 kg/m3, 4.66 kWh/m3 and 0.44 US$/m3, respectively. The removal efficiencies of chemical oxygen demand (COD), biological oxygen demand (BOD), total suspended solid (TSS), turbidity and color were 97.10%, 95.55%, 98%, 96% and 98.50%, respectively, at the first 10 min of reaction time, while the phenol compound of the wastewater was almost entirely removed (99.99%). The experimental results confirm that the new reactor design with rotated anode impellers and cathode rings provided high treatment efficiency at a reduced reaction time and with lower energy consumption.

A novel Rotated Electrocoagulation Reactor.Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Environmental Management - Volume 176, 1 July 2016, Pages 34–44
نویسندگان
, , , ,