کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1163153 1490930 2016 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Profiling and relative quantification of phosphatidylethanolamine based on acetone stable isotope derivatization
ترجمه فارسی عنوان
شمارش و اندازه گیری نسبی فسفاتیدیلتانولامین براساس مشتق شدن ایزوتوپ پایدار استون
کلمات کلیدی
فسفاتیدیلتانولامین، مشتق شده از ایزوتوپ پایدار استون، طیف سنجی جرمی، اندازه گیری نسبی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• A novel isotope reagent acetone was explored for the derivatization of PEs.
• The labeling reaction was carried out under mild conditions with high specificity.
• Enhanced detection sensitivity of PEs was achieved after derivatization.
• The ASID-DNLS-Shotgun MS/MS method was used to relative quantification of PEs.

Phosphatidylethanolamine (PE) is considered to be one of the pivotal lipids for normal cellular function as well as disease initiation and progression. In this study, a simple, efficient, reliable, and inexpensive method for the qualitative analysis and relative quantification of PE, based on acetone stable isotope derivatization combined with double neutral loss scan-shotgun electrospray ionization tandem-quadrupole mass spectrometry analysis (ASID-DNLS-Shotgun ESI-MS/MS), was developed. The ASID method led to alkylation of the primary amino groups of PE with an isopropyl moiety. The use of acetone (d0-acetone) and deuterium-labeled acetone (d6-acetone) introduced a 6 Da mass shift that was ideally suited for relative quantitative analysis, and enhanced sensitivity for mass analysis. The DNLS model was introduced to simultaneously analyze the differential derivatized PEs by shotgun ESI-MS/MS with high selectivity and accuracy. The reaction specificity, labeling efficiency, and linearity of the ASID method were thoroughly evaluated in this study. Its excellent applicability was validated by qualitative and relative quantitative analysis of PE species presented in liver samples from rats fed different diets. Using the ASID-DNLS-Shotgun ESI-MS/MS method, 45 PE species from rat livers have been identified and quantified in an efficient manner. The level of total PEs tended to decrease in the livers of rats on high fat diets compared with controls. The levels of PE 32:1, 34:3, 34:2, 36:3, 36:2, 42:10, plasmalogen PE 36:1 and lyso PE 22:6 were significantly reduced, while levels of PE 36:1 and lyso PE 16:0 increased.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 902, 1 January 2016, Pages 142–153
نویسندگان
, , , , , , , , ,