کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1163334 1490939 2015 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Bovine serum albumin as a universal suppressor of non-specific peptide binding in vials prior to nano-chromatography coupled mass-spectrometry analysis
ترجمه فارسی عنوان
آلبومین سرم گاو به عنوان یک سرکوبگر جهانی از اتصال پپتید غیر اختصاصی در ویال ها قبل از تجزیه و تحلیل توده اسپکترومتری توسط نانو کروماتوگرافی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• NSB to polypropylene vials for complex peptide mixtures was analyzed.
• Different agents were analyzed for NSB suppression and nanoLC-MS/MS compatibility.
• Peptide and protein matrices block NSB.
• In the peptide matrix ionization suppression of target peptides was observed.
• 0.1% BSA NSB blockader is fully compatible with nanoLC-MS/MS analysis.

Non-specific binding (NSB) is a well-known problem for any application that deals with ultralow analyte quantities. The modern nano-flow chromatography coupled tandem mass-spectrometry (nanoLC-MS/MS) works with the lowest conceivable analyte concentrations. However, while the NSB problem is widely accepted and investigated for metabolomics and single-peptide medicine-related assays, its impact is not studied for complex peptide mixtures in proteomic applications. In this work peptide NSB to a common plastic autosampler vial was studied for a model mixture of 46 synthetic peptides. A significant NSB level was demonstrated for total peptide concentrations of up to 1 mg mL−1. Different agents were tried for NSB suppression and compatibility with nanoLC-MS/MS analysis: a chaotropic agent, an amino acid mixture, a peptide mixture and a protein solution. The first two were inefficacious. The peptide matrix blocked NSB, however, it also led to analyte ionization suppression in nanoLC-MS/MS. The protein solution (0.1% BSA) efficiently eliminated NSB, while a trap-elute nanoHPLC configuration together with a small-pore reverse-phased sorbent effectively and quantitatively extracted the model peptides and depleted protein material from the sample. Higher protein concentration partially impeded peptide extraction. Thus, the 0.1% BSA solution might be regarded as an effective non-interfering blockader of NSB for sample resuspension and storage in an autosampler prior to LC-MS/MS analysis.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 893, 17 September 2015, Pages 57–64
نویسندگان
, , , , ,