کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1163510 1490943 2015 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
A novel method for the rapid determination of polyethoxylated tallow amine surfactants in water and sediment using large volume injection with high performance liquid chromatography and tandem mass spectrometry
ترجمه فارسی عنوان
یک روش جدید برای تعیین سریع سورفکتانتهای آمینو سدیم پلی اتیل کولتییل در آب و رسوب با استفاده از حجم زیاد با استفاده از کروماتوگرافی مایع با کارایی بالا و طیف سنجی جرم دو طرفه
کلمات کلیدی
آمین های کاهنده پلی اتیل کربنات، سورفکتانتهای گلیفسات، اب، رسوب، اسپکترومتر جرمی کروماتوگرافی مایع با عملکرد بالا، تزریق حجم زیاد
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• We present a new method for quantifying POEA surfactants in water and sediment.
• Our method provides greater speed and sensitivity than other methods.
• Loss of POEA during storage is prevented by adding methanol to aqueous samples.
• Surfactants like MON 0818 can now be measured at biologically relevant concentrations.

Polyethoxylated tallow amine (POEA) surfactants have been used in many glyphosate-based herbicide formulations for agricultural, industrial and residential weed control. The potential for release of these compounds into the environment is of increasing concern due to their toxicity towards aquatic organisms. Current methods for analysis of POEA surfactants require significant time and effort to achieve limits of quantification that are often higher than the concentrations at which biological effects have been observed (as low as 2 ng mL−1). We have developed a rapid and robust method for quantifying the POEA surfactant mixture MON 0818 at biologically relevant concentrations in fresh water, sea water and lake sediment using reversed phase high-performance liquid chromatography and electrospray ionization-tandem mass spectrometry. Water samples preserved by 1:1 v/v dilution with methanol are analyzed directly following centrifugation. Sediment samples undergo accelerated solvent extraction in aqueous methanol prior to analysis. Large volume (100 μL) sample injection and multiple reaction monitoring of a subset of the most abundant POEA homologs provide limits of quantification of 0.5 and 2.9 ng mL−1 for MON 0818 in fresh water and sea water, respectively, and 2.5 ng g−1 for total MON 0818 in lake sediment. Average recoveries of 93 and 75% were achieved for samples of water and sediment, respectively spiked with known amounts of MON 0818. Precision and accuracy for the analysis of water and sediment samples were within 10 and 16%, respectively based upon replicate analyses of calibration standards and representative samples. Results demonstrate the utility of the method for quantifying undegraded MON 0818 in water and sediment, although a more comprehensive method may be needed to identify and determine other POEA mixtures and degradation profiles that might occur in the environment.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 889, 19 August 2015, Pages 147–155
نویسندگان
, ,