کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1164457 1491034 2013 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Quantum dots based electrochemiluminescent immunosensor by coupling enzymatic amplification for ultrasensitive detection of clenbuterol
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Quantum dots based electrochemiluminescent immunosensor by coupling enzymatic amplification for ultrasensitive detection of clenbuterol
چکیده انگلیسی


• An ultrasensitive ECL immunosensor of CdSe QDs for clenbuterol determination is developed.
• The CdSe QDs showed great biocompatibility and could be easier to make direct use of such QDs in the region of biological system.
• Enzymatic amplification strategy was proposed by combining the coreactant and pAb/GaRIgG-HRP.
• Enzymatic amplification increased ECL emission and extended the analyte in presence of substrate.
• It provided a method for detecting clenbuterol and enlarged the usage of QDs in ECL biosensing.

An ultrasensitive electrochemiluminescence (ECL) immunosensor based on CdSe quantum dots (QDs) has been designed for the detection of clenbuterol. The immunosensor was fabricated by layer by layer and characterized with atomic force microscopic images (AFM) and electrochemical impedance spectra (EIS). In oxygen-saturated pH = 9.0 Tris-HCl buffer, a strong ECL emission of QDs could be observed during the cathodic process due to the H2O2 product from electrochemical reduction of dissolved oxygen. Upon the formation of immunocomplex, the second antibody labeled with horseradish peroxidase was simply immobilized on the electrode surface. The ECL emission decreased since steric hindrance of the immunocomplex slowed down the electron-transfer speed of dissolved oxygen, and also could be greatly amplified by an enzymatic cycle to consume the self-produced coreactant. Using clenbuterol as model analyte, the ECL intensity was determined by the concentration of competitive immunoassay of clenbuterol with a wide calibration in the range of 0.05 ng mL−1 to 1000 ng mL−1, and a low detection limit was 0.02 ng mL−1. The immunosensor shows good stability and fabrication reproducibility. It was applied to detecting practical samples with the satisfactory results. This immunosensing strategy opens a new avenue for detection of residue and application of QDs in ECL biosensing.

Figure optionsDownload as PowerPoint slide

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 798, 10 October 2013, Pages 82–88
نویسندگان
, , , , ,