کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1166945 960519 2011 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Characterization of a novel particle into liquid sampler for analysis of single fluorescent aerosol particles through capillary electrophoresis
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Characterization of a novel particle into liquid sampler for analysis of single fluorescent aerosol particles through capillary electrophoresis
چکیده انگلیسی

An approach to sample and analyze single aerosolized droplets (<10 nL) of solutions containing fluorescein isothiocyanate (FITC) labeled glycine (GLY) and glutamic acid (GLU) is demonstrated. The sampling approach is based on inertial impaction in which the sample particle is accelerated through a nozzle and directly into a small drop of buffered solution (20 mM borate, pH = 10) suspended at the end of a coaxial tube of stainless steel and a fused silica capillary. A spherical light scattering cell and laser (λ = 532 nm) is used to detect the arrival of particles at the buffered droplet. Upon dissolution and/or mixing, a portion of the sample is injected onto the fused silica capillary for subsequent chemical analysis by capillary electrophoresis (CE) and detection by laser-induced fluorescence (LIF). It was found that the inertial impaction approach sampled particles >1 μm diameter with an efficiency of 80% or greater. At 15 kV applied potential, the FITC conjugates of GLY and GLU could be resolved in less than 120 s allowing qualitative analysis of the contents of single dispersed particles. However, the extent to which the sample is diluted into the buffer droplet varied significantly on a per-particle basis that caused >80% R.S.D. in fluorescence peak heights. This aspect of the method would necessitate the use of internal standards for quantitative analysis of materials present within the particles. It is envisaged that further improvements to the device described may ultimately lead to analysis of the contents of single particles dispersed in earth's atmosphere.

Figure optionsDownload as PowerPoint slideHighlights
• Sampling individual aqueous aerosol droplets into a fused silica capillary for CE analysis has been achieved.
• Collection efficiencies of >80% have been observed for super-micron particles.
• Separation of chemical components in particles has been achieved in 120 s.
• Dilution of particle material during sampling was highly variable.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Analytica Chimica Acta - Volume 702, Issue 1, 19 September 2011, Pages 120–126
نویسندگان
, , ,