کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1198869 1493532 2015 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simultaneous determination of polar and apolar compounds in environmental samples by a polyaniline/hydroxyl multi-walled carbon nanotubes composite-coated stir bar sorptive extraction coupled with high performance liquid chromatography
ترجمه فارسی عنوان
تعیین همزمان ترکیبات قطبی و آپولو در نمونه های محیطی با استفاده از نانولوله های کربنی پلیانیلین / هیدروکسیل چند جداره کربن ترکیب شده با استخراج سنگ شکن مخلوط با کروماتوگرافی مایع با کارایی بالا
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• PANi/MWCNTs-OH composite-coated stir bar was prepared via the adhesion technique.
• The preparation of PANi/MWCNTs-OH composite-coated stir bars is simple and reproducible.
• PANi/MWCNTs-OH composite coating can simultaneously extract polar and apolar analytes.
• A novel method of PANi/MWCNTs-OH-SBSE-HPLC–UV was developed for environmental analysis.

Developing novel coatings for stir bar sorptive extraction (SBSE) is essential for extending the application of SBSE. Herein, a polyaniline/hydroxyl multi-walled carbon nanotubes (PANi/MWCNTs-OH) composite-coated stir bar was prepared via the adhesion technique for the simultaneous extraction of polar and apolar compounds, and a novel method of PANi/MWCNTs-OH-coated SBSE coupled with high performance liquid chromatography-ultraviolet detection (HPLC–UV) was proposed. To test the extraction performance of PANi/MWCNTs-OH-coated stir bar, phenols, non-steroidal anti-inflammatory drugs, and polychlorinated biphenyls were selected as representatives for polar, semi-polar and apolar compounds, respectively. High enrichment factors (EFs) ranged from 20.4 to 60.4-fold (theoretical EF, 100-fold) for target analytes were achieved, indicating that the proposed method is applicable in simultaneous analysis of the compounds with different polarities. The prepared PANi/MWCNTs-OH-coated stir bar has a good preparation reproducibility and can be reused for 20 times. The limits of detection (LODs, S/N = 3) were found to be in the range of 0.09–0.81 μg/L. To validate the applicability, the proposed method was successfully applied to the analysis of eight target analytes in Yangtze River water after filtration and in the extract from sediment samples.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1394, 15 May 2015, Pages 36–45
نویسندگان
, , , ,