کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
1198889 1493489 2016 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Application of modified stir bar with nickel:zinc sulphide nanoparticles loaded on activated carbon as a sorbent for preconcentration of losartan and valsartan and their determination by high performance liquid chromatography
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Application of modified stir bar with nickel:zinc sulphide nanoparticles loaded on activated carbon as a sorbent for preconcentration of losartan and valsartan and their determination by high performance liquid chromatography
چکیده انگلیسی


• A new stir bar sorptive extraction method was proposed for losartan and valsartan.
• Ni:ZnS NPs loaded on activated carbon was used as the coating material for stir bar.
• Important parameters effecting the extraction were optimized by chemomotery method.
• The preconcentrated analytes were determined by HPLC.
• The method was applied to the determination of analytes in urine and plasma samples.

In this study, the stir bar was coated for the first time with the ​nicel:zins sulphide nanoparticles (Ni:ZnS NPs) loaded on activated carbon (AC) (Ni:ZnS-AC) as well as 1-ethyl-3-methylimidazolium hexafluorophosphate ionic liquid (IL) using sol gel technique and was used for stir bar sorptive extraction (SBSE) of losartan (LOS) and valsartan (VAL) as the model compounds. The extracted analytes were then quantified by high performance liquid chromatography (HPLC) equipped with an ultra violet detector. The best extraction performance for LOS and VAL was obtained through the optimization of the parameters affecting SBSE including pH of sample solution, ionic strength, extraction time, volume of desorption solvent, desorption time, and stirring speed. The fractional factorial design (FFD) was used to find the most important parameters, which were then optimized by the central composite design (CCD) and the desirability function (DF). Under the optimal experimental conditions, wide linear ranges of 0.4–50 μg L−1 and 0.5–50 μg L−1 and good RSDs (at level of 5 μg L−1 and n = 6) of 4.4 and 4.9% were obtained for LOS and VAL, respectively. With the enrichment factors (EFs) of 188.6 and 184.8-fold, the limits of detection (LODs, S/N = 3) of the developed method were found to be 0.12 and 0.15 μg L−1 for LOS and VAL, respectively. The developed method was successfully applied to the determination of LOS and VAL in urine and plasma matrices.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Chromatography A - Volume 1437, 11 March 2016, Pages 15–24
نویسندگان
, , , , ,