Effect of reference conditions on flow rate, modifier fraction and retention in supercritical fluid chromatography
ترجمه فارسی عنوان
تأثیر شرایط مرجع بر میزان جریان، ضریب اصلاح شده و نگهداری در کروماتوگرافی سیال فوق کریتی
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• The pressure dependence of flow rate and fraction of modifier in SFC is investigated.
• These parameters can be defined at fixed or variable reference conditions.
• A system with fixed reference conditions is independent of operating pressure.
• For variable reference conditions: volumetric parameters change with operating pressure.
• Retention in SFC is determined by mass fraction of modifier.

When using compressible mobile phases such as fluidic CO2, the density, the volumetric flow rates and volumetric fractions are pressure dependent. The pressure and temperature definition of these volumetric parameters (referred to as the reference conditions) may alter between systems, manufacturers and operating conditions. A supercritical fluid chromatography system was modified to operate in two modes with different definition of the eluent delivery parameters, referred to as fixed and variable mode. For the variable mode, the volumetric parameters are defined with reference to the pump operating pressure and actual pump head temperature. These conditions may vary when, e.g. changing the column length, permeability, flow rate, etc. and are thus variable reference conditions. For the fixed mode, the reference conditions were set at 150 bar and 30 °C, resulting in a mass flow rate and mass fraction of modifier definition which is independent of the operation conditions. For the variable mode, the mass flow rate of carbon dioxide increases with system pump operating pressure, decreasing the fraction of modifier. Comparing the void times and retention factor shows that the deviation between the two modes is almost independent of modifier percentage, but depends on the operating pressure. Recalculating the set volumetric fraction of modifier to the mass fraction results in the same retention behaviour for both modes. This shows that retention in SFC can be best modelled using the mass fraction of modifier. The fixed mode also simplifies method scaling as it only requires matching average column pressure.